{"id":913,"date":"2024-11-22T09:09:19","date_gmt":"2024-11-22T01:09:19","guid":{"rendered":"http:\/\/huiganis.com\/?p=913"},"modified":"2024-11-29T10:03:56","modified_gmt":"2024-11-29T02:03:56","slug":"sm39pwb-cy%e5%9e%8b%e5%b7%ae%e5%8e%8b%e5%8f%98%e9%80%81%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.huiganis.com\/en\/sm39pwb-cy%e5%9e%8b%e5%b7%ae%e5%8e%8b%e5%8f%98%e9%80%81%e5%99%a8\/","title":{"rendered":"SM39PWB-CY differential pressure transmitter"},"content":{"rendered":"<p>SM39PWB-CY differential pressure transmitter is used to measure the level, density, pressure, and flow of liquid, gas or steam, and then convert it into 4mA~20mADC HART current signal output. It can also communicate with HART handheld terminal for parameter setting, process monitoring, etc.<\/p>\n\n\n\n<p><strong>Standard Specifications<\/strong><\/p>\n\n\n\n<p>(The range is adjusted based on the standard zero point, stainless steel 316L diaphragm, and the filling liquid is silicone oil)<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><em>Performance Specifications<\/em><\/li>\n<\/ol>\n\n\n\n<p>Reference accuracy of span adjustment (including linearity, hysteresis and repeatability from zero point):<\/p>\n\n\n\n<p>\u00b1 0.075% If TD&gt;10 (TD=maximum range\/adjustment range), then: \u00b1(0.0075\u00d7TD)%<\/p>\n\n\n\n<p>The square root output accuracy is 1.5 times the linear reference accuracy above.<\/p>\n\n\n\n<p><strong>Ambient temperature influence<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Range code<\/strong><\/td><td>-20\u2103\uff5e65\u2103 total impact<\/td><td><strong>Range code<\/strong><\/td><td>Total impact of -40\u2103\uff5e-20\u2103 and 65\u2103\uff5e85\u2103<\/td><\/tr><tr><td>A<\/td><td>\u00b1(0.45\u00d7TD+0.25)%\u00d7Span<\/td><td>A<\/td><td>\u00b1(0.45\u00d7TD+0.25)%\u00d7Span<\/td><\/tr><tr><td>B<\/td><td>\u00b1(0.30\u00d7TD+0.20)%\u00d7Span<\/td><td>B<\/td><td>\u00b1(0.30\u00d7TD+0.20)%\u00d7Span<\/td><\/tr><tr><td>C\/D\/F<\/td><td>\u00b1(0.20\u00d7TD+0.10)%\u00d7Span<\/td><td>C\/D\/F<\/td><td>\u00b1(0.20\u00d7TD+0.10)%\u00d7Span<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><em>Over range impact<\/em><\/p>\n\n\n\n<p>\u00b10.075%\u00d7Span<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Static pressure effect<\/em><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Range code<\/strong><\/td><td><strong>Impact<\/strong><\/td><\/tr><tr><td>A<\/td><td>\u00b1(0.5%Span)\/4MPa<\/td><\/tr><tr><td>B<\/td><td>\u00b1(0.3%Span)\/16MPa<\/td><\/tr><tr><td>F\/G\/H\/I\/J<\/td><td>\u00b1(0.1%Span)\/16MPa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Overvoltage Effect<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Range code<\/strong><\/td><td><strong>Impact<\/strong><\/td><\/tr><tr><td>A<\/td><td>\u00b10.5%\u00d7Span\/4MPa<\/td><\/tr><tr><td>B\/C\/D\/E<\/td><td>\u00b10.2%\u00d7Span\/16MPa<\/td><\/tr><tr><td>F\/G\/H\/I\/J<\/td><td>\u00b10.1%\u00d7Span\/16MPa<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Long-term stability<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Range code<\/strong><\/td><td colspan=\"2\"><strong>Impact<\/strong><\/td><\/tr><tr><td>A<\/td><td>\u00b10.5%\u00d7Span\/1<\/td><td>Year<\/td><\/tr><tr><td>B<\/td><td>\u00b10.2%\u00d7Span\/1<\/td><td>Year<\/td><\/tr><tr><td>F\/G\/H\/I\/J<\/td><td>\u00b10.1%\u00d7Span\/1<\/td><td>Year<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Power supply impact<\/strong><\/p>\n\n\n\n<p>\u00b10.001% \/10V (12\uff5e42V DC), can be ignored.<\/p>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li><em>Functional specifications<\/em><\/li>\n<\/ol>\n\n\n\n<p><strong>Range and scope<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">Range<\/td><td>kPa<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;A<\/td><td>Range<\/td><td>0\uff5e1<\/td><\/tr><tr><td>scope<\/td><td>-3000\uff5e3000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;B<\/td><td>Range<\/td><td>1\uff5e100<\/td><\/tr><tr><td>scope<\/td><td>-16000\uff5e16000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;C<\/td><td>Range<\/td><td>100\uff5e500<\/td><\/tr><tr><td>scope<\/td><td>-16000\uff5e16000<\/td><\/tr><tr><td rowspan=\"2\">D<\/td><td>Range<\/td><td>500\uff5e3000<\/td><\/tr><tr><td>scope<\/td><td>-16000\uff5e16000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;E<\/td><td>Range<\/td><td>3000\uff5e4000<\/td><\/tr><tr><td>scope<\/td><td>-16000\uff5e16000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;F<\/td><td>Range<\/td><td>4000\uff5e10000<\/td><\/tr><tr><td>scope<\/td><td>-16000\uff5e16000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;G<\/td><td>Range<\/td><td>1\uff5e100<\/td><\/tr><tr><td>scope<\/td><td>16000\uff5e30000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;H<\/td><td>Range<\/td><td>100\uff5e500<\/td><\/tr><tr><td>scope<\/td><td>16000\uff5e30000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;I<\/td><td>Range<\/td><td>500\uff5e3000<\/td><\/tr><tr><td>scope<\/td><td>16000\uff5e30000<\/td><\/tr><tr><td rowspan=\"2\">&nbsp;J<\/td><td>Range<\/td><td>3000\uff5e4000<\/td><\/tr><tr><td>scope<\/td><td>16000\uff5e30000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><strong>Range limit<\/strong><\/p>\n\n\n\n<p>It can be adjusted arbitrarily within the upper and lower limits of the measuring range.<\/p>\n\n\n\n<p>It is recommended to select a range code with the lowest possible turndown ratio to optimize performance characteristics.&nbsp;<strong>Zero setting<\/strong><\/p>\n\n\n\n<p>The zero point and span can be adjusted to any value within the measuring range in the table, as long as: the calibration span \u2265 the minimum span<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Installation location affects<\/em><\/h3>\n\n\n\n<p>The change of the installation position parallel to the diaphragm surface will not cause zero drift. If the installation position changes more than 90\u00b0 from the diaphragm surface, a zero position effect within the range of &lt;0.4kPa will occur, which can be corrected by adjusting the zero. No range effect.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Output<\/em><\/h3>\n\n\n\n<p>Two-wire system, 4mA~20mADC, optional HART output digital communication, optional linear or square root output. Output signal limit: Imin=3.9mA, Imax=20.5mA<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Response time<\/em><\/h3>\n\n\n\n<p>The amplifier component damping constant is 0.1s; the sensor time constant is 0.1s to 1.6s, depending on the range and range ratio. The additional adjustable time constant is: 0.1s to 60s. The impact on non-linear outputs (such as square root function) depends on this function and can be calculated accordingly.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Warm-up time<\/em><\/h3>\n\n\n\n<p>\uff1c15s<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Ambient temperature<\/em><\/h3>\n\n\n\n<p>-40\u2103\uff5e85\u2103<\/p>\n\n\n\n<p>With LCD display and fluoro rubber seal -20\u2103\uff5e65\u2103&nbsp;<strong>Storage temperature\/transportation temperature<\/strong><\/p>\n\n\n\n<p>-50\u2103\uff5e85\u2103; with LCD display: -40\u2103\uff5e85\u2103&nbsp;<strong>Work Pressure<\/strong><\/p>\n\n\n\n<p>Rated working pressure is divided into three levels: 16MPa, 25MPa, 40MPa<strong>Static pressure limit<\/strong><\/p>\n\n\n\n<p>From 3.5kPa absolute pressure to rated pressure, the protection pressure can be greater than 1.5 times the rated pressure and applied to both sides of the transmitter at the same time.<strong>One-way overload limit<\/strong>:<\/p>\n\n\n\n<p>One-way overload up to rated pressure<strong>Electromagnetic compatibility (EMC)<\/strong><\/p>\n\n\n\n<p>See the Electromagnetic Compatibility Appendix on the next page<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><em>Install<\/em><\/li>\n<\/ol>\n\n\n\n<p><strong>Power supply and load conditions<\/strong><\/p>\n\n\n\n<p>The power supply voltage is 24V, R\u2264(Us-12V)\/Imax k\u03a9, where Imax=23 mA<\/p>\n\n\n\n<p>Maximum power supply voltage: 42VDC<\/p>\n\n\n\n<p>Minimum power supply voltage: 12VDC, 15VDC (backlit LCD display) Digital communication load range: 250\u03a9\uff5e600\u03a9<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Electrical Connections<\/em><\/h3>\n\n\n\n<p>M20\u00d71.5 cable gland, terminal block is suitable for wires of 0.5mm2~2.5mm2.<strong>Process connection<\/strong><\/p>\n\n\n\n<p>Both ends of the process connection flange have NPT 1\/4 and UNF 7\/16&quot; internal threads.<\/p>\n\n\n\n<ol start=\"2\" class=\"wp-block-list\">\n<li><em>Physical specifications<\/em><\/li>\n<\/ol>\n\n\n\n<p><strong>Material<\/strong><\/p>\n\n\n\n<p>Measuring membrane box: stainless steel 316L<\/p>\n\n\n\n<p>Diaphragm: Stainless steel 316L, Hastelloy C Process flange: Stainless steel 304<\/p>\n\n\n\n<p>Nuts and bolts: Stainless steel (A4) Filling fluid: Silicone oil<\/p>\n\n\n\n<p>Sealing ring: Nitrile rubber (NBR), fluororubber (FKM), polytetrafluoroethylene (PTFE) Transmitter housing: Aluminum alloy, with epoxy resin sprayed on the surface<\/p>\n\n\n\n<p>Shell seal: Nitrile rubber (NBR) Nameplate: Stainless steel 304<\/p>\n\n\n\n<p><strong>weight:&nbsp;<\/strong>3.3kg (without: LCD display, mounting bracket, process connection)<\/p>\n\n\n\n<p><strong>Enclosure protection grade<\/strong>IP67<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Electromagnetic compatibility table<\/em><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>Serial number<\/td><td>Test items<\/td><td>Basic Standards<\/td><td>Test conditions<\/td><td>Performance level<\/td><\/tr><tr><td>1<\/td><td>Radiated interference (housing)<\/td><td>GB\/T 9254-2008 Table 5<\/td><td>30MHz\uff5e1000MHz<\/td><td>qualified<\/td><\/tr><tr><td>&nbsp;2<\/td><td>Conducted interference (DC power port)<\/td><td>&nbsp;GB\/T 9254-2008 Table 1<\/td><td>&nbsp;0.15MHz\uff5e30MHz<\/td><td>&nbsp;qualified<\/td><\/tr><tr><td>&nbsp;3<\/td><td>&nbsp;Electrostatic Discharge (ESD) Immunity<\/td><td>&nbsp;GB\/T 17626.2-2006<\/td><td>4kV (contact) 8kV (air)<\/td><td>&nbsp;B<\/td><\/tr><tr><td>&nbsp;4<\/td><td>&nbsp;Radio frequency electromagnetic field immunity<\/td><td>&nbsp;GB\/T 17626.3-2006<\/td><td>10V\/m(80MHz\uff5e1GHz)<\/td><td>&nbsp;A<\/td><\/tr><tr><td>5<\/td><td>Power frequency magnetic field immunity<\/td><td>GB\/T 17626.8-2006<\/td><td>30A\/m<\/td><td>A<\/td><\/tr><tr><td>6<\/td><td>Electrical fast transient burst immunity<\/td><td>GB\/T 17626.4-2008<\/td><td>2kV(5\/50ns,5kHz)<\/td><td>B<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Note 1: A performance level description: When tested, performance is normal within the technical specification limits.<\/p>\n\n\n\n<p>Note 2: Description of performance level B: During the test, the function or performance is temporarily reduced or lost, but it can recover by itself, and the actual operating status, storage and data are not changed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Dimensions<\/em>Unit is mm<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"626\" height=\"835\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_1-10.webp\" alt=\"\" class=\"wp-image-1481\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_1-10.webp 626w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_1-10-225x300.webp 225w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_1-10-9x12.webp 9w\" sizes=\"auto, (max-width: 626px) 100vw, 626px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"647\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4-1024x647.webp\" alt=\"\" class=\"wp-image-1482\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4-1024x647.webp 1024w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4-300x190.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4-768x486.webp 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4-18x12.webp 18w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image_2-4.webp 1169w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1001\" height=\"645\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-1-4.webp\" alt=\"\" class=\"wp-image-1484\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-1-4.webp 1001w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-1-4-300x193.webp 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-1-4-768x495.webp 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-1-4-18x12.webp 18w\" sizes=\"auto, (max-width: 1001px) 100vw, 1001px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>SM39PWB-CY\u578b\u5dee\u538b\u53d8\u9001\u5668\u7528\u4e8e\u6d4b\u91cf\u6db2\u4f53\u3001\u6c14\u4f53\u6216\u84b8\u6c7d\u7684\u6db2\u4f4d\u3001\u5bc6\u5ea6\u3001\u538b\u529b\u3001\u4ee5\u53ca\u6d41\u91cf\uff0c\u7136\u540e\u5c06\u5176\u8f6c\u53d8\u6210&#038;nbsp [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[45],"tags":[],"class_list":["post-913","post","type-post","status-publish","format-standard","hentry","category-differential-pressure-transmitter"],"_links":{"self":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/913","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/comments?post=913"}],"version-history":[{"count":2,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/913\/revisions"}],"predecessor-version":[{"id":1485,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/913\/revisions\/1485"}],"wp:attachment":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/media?parent=913"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/categories?post=913"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/tags?post=913"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}