{"id":934,"date":"2024-11-22T09:58:45","date_gmt":"2024-11-22T01:58:45","guid":{"rendered":"http:\/\/huiganis.com\/?p=934"},"modified":"2024-11-28T13:00:02","modified_gmt":"2024-11-28T05:00:02","slug":"sm39%ef%bc%8ddh01t%e5%9e%8bhart%e5%8d%8f%e8%ae%ae%e6%99%ba%e8%83%bd%e6%b8%a9%e5%ba%a6%e5%8f%98%e9%80%81%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.huiganis.com\/en\/sm39%ef%bc%8ddh01t%e5%9e%8bhart%e5%8d%8f%e8%ae%ae%e6%99%ba%e8%83%bd%e6%b8%a9%e5%ba%a6%e5%8f%98%e9%80%81%e5%99%a8\/","title":{"rendered":"SM39-DH01T HART protocol intelligent temperature transmitter"},"content":{"rendered":"<p>1. Overview<\/p>\n\n\n\n<p>SM39-DH01T HART protocol intelligent temperature transmitter is a high-precision, high-stability, multi-parameter, 4.5-digit LCD display intelligent temperature measurement product that complies with the HART protocol. Users can use the HART communicator to manage, adjust or monitor process variables of the HART instrument running in the process, or use buttons for on-site configuration, which is easy to operate. Precision digital nonlinear correction technology, safe and reliable explosion-proof structure design and standardized signal output, high accuracy, wide range coverage, suitable for places where precision measurement is required. This product works in a two-wire mode and can directly replace the analog two-wire 4-20mADC output transmitter. It can be widely used in various fields such as petroleum, chemical, steel, electric power, building materials, textiles, pharmaceuticals, food, gas, scientific experiments and military industry. It has been promoted and applied in oil fields such as Daqing, North China, Xinjiang, etc., and has won user recognition for its high accuracy, high reliability, simple installation, convenient maintenance, environmental protection and durability.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">2. Features<\/h1>\n\n\n\n<p>4~20mA current output superimposed with HART\uf0ae protocol digital communication (two-wire system);<\/p>\n\n\n\n<p>\u00b7Adopt digital nonlinear correction technology;<\/p>\n\n\n\n<p>On-site key operation is available for easy configuration;<\/p>\n\n\n\n<p>\u00b7Protection grade IP67.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">3. Performance indicators<\/h1>\n\n\n\n<p>Measuring range: -200\uff5e650\u2103 (customizable);<\/p>\n\n\n\n<p>Accuracy: \u00b10.5 %FS (customizable)<\/p>\n\n\n\n<p>Working temperature: -20\u2103\uff5e80\u2103<\/p>\n\n\n\n<p>Storage temperature: -40\u2103\uff5e85\u2103<\/p>\n\n\n\n<p>Power supply: (15\uff5e30) VDC (24VDC recommended)<\/p>\n\n\n\n<p>Digital output: (4~20)mADC output superimposed with HART\uf0e2 protocol digital communication<\/p>\n\n\n\n<p>Display: LCD display, two\/three-button control<\/p>\n\n\n\n<p>Damping: (0\uff5e32)s<\/p>\n\n\n\n<p>Insulation: 100M\u03a9\/50V<\/p>\n\n\n\n<p>O-ring: Fluororubber<\/p>\n\n\n\n<p>Weight: Approx. 1.7kg<\/p>\n\n\n\n<p>Protection grade: IP67;<\/p>\n\n\n\n<p>Explosion-proof certificate number: CE18.1518 Explosion-proof mark: Exd IIc T4 Gb.<\/p>\n\n\n\n<h1 class=\"wp-block-heading\">4. Appearance and structure (unit: mm)<\/h1>\n\n\n\n<p>The appearance structure is shown in Figure 1.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"280\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93-1024x280.png\" alt=\"\" class=\"wp-image-1376\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93-1024x280.png 1024w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93-300x82.png 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93-768x210.png 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93-18x5.png 18w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-93.png 1276w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">5. Installation&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/h2>\n\n\n\n<p>The general installation method is: the sensor probe sleeve is welded on the pipeline (or the device to be measured), and the sensor is screwed on the probe sleeve. The following is the installation instructions for the oil pipe of the pumping unit, and other applications are similar.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"831\" height=\"611\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-94.png\" alt=\"\" class=\"wp-image-1377\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-94.png 831w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-94-300x221.png 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-94-768x565.png 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-94-16x12.png 16w\" sizes=\"auto, (max-width: 831px) 100vw, 831px\" \/><\/figure>\n\n\n\n<p>The operation process is (as shown in Figure 2):<\/p>\n\n\n\n<p>(1) Close the valve of the oil pipeline and release the pressure. Open a hole in the oil pipeline that is slightly larger than the outer diameter of the sensor probe base;<\/p>\n\n\n\n<p>(2) Insert the base from the opening to the maximum depth, adjust the base to form a 45\u00b0 inclination with the oil flow, and then seal and weld it to the oil pipe along the hole;<\/p>\n\n\n\n<p>(3) Inject heat transfer oil into the base, about 2\/5 of the volume of the tube;<\/p>\n\n\n\n<p>(4) Insert the temperature sensor probe into the base, tighten the sensor with a wrench stuck in the hexagonal prism, and open the pipeline valve to restore.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"711\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95-1024x711.png\" alt=\"\" class=\"wp-image-1378\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95-1024x711.png 1024w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95-300x208.png 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95-768x534.png 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95-18x12.png 18w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-95.png 1107w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">6. Electrical connection<\/h2>\n\n\n\n<p>Open the back cover of the instrument (terminal side) to see the terminal blocks. The power connection is shown in Figure 4: 1 (red) and 2 (black) on the left are for sensor power supply and signal wiring, regardless of positive or negative polarity. The 4 pins on the top are the fixed ends of the grounding wire and shielding wire.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"547\" src=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96-1024x547.png\" alt=\"\" class=\"wp-image-1380\" srcset=\"https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96-1024x547.png 1024w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96-300x160.png 300w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96-768x410.png 768w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96-18x10.png 18w, https:\/\/lingjuimg.com\/wp-content\/uploads\/zhonkehuigan\/2024\/11\/image-96.png 1249w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">7. Notes<\/h2>\n\n\n\n<p>7.1. All sensors are digitally calibrated, and different sensors are completely consistent and interchangeable.<\/p>\n\n\n\n<p>7.2. Connect the sensor power supply and signal wiring to the left end of the three-core terminal POWER1+ (red) and POWER 2- (black), install and tighten the back cover. Pay attention to tighten the sheath to prevent water leakage.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>1.\u6982\u8ff0 SM39\uff0dDH01T\u578bHART\u534f\u8bae\u667a\u80fd\u6e29\u5ea6\u53d8\u9001\u5668\u662f\u4e00\u6b3e\u9ad8\u7cbe\u5ea6\u3001\u9ad8\u7a33\u5b9a\u6027\u3001\u591a\u53c2\u6570\u30014\u4f4d\u534a LCD \u663e\u793a [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[44],"tags":[],"class_list":["post-934","post","type-post","status-publish","format-standard","hentry","category-temperature-transmitter"],"_links":{"self":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/comments?post=934"}],"version-history":[{"count":3,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/934\/revisions"}],"predecessor-version":[{"id":1381,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/posts\/934\/revisions\/1381"}],"wp:attachment":[{"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/media?parent=934"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/categories?post=934"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.huiganis.com\/en\/wp-json\/wp\/v2\/tags?post=934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}